Mineola (V)
Public water district serving Mineola · approximately 20,600 residents.
Submitting a DOH-1013
Receives submissions by email.
Mineola (V) currently accepts DOH-1013 backflow test submissions by email. Potaflow can deliver your test on your behalf with a timestamped delivery record.
District rules
Backflow testing in Mineola (V)
What Mineola (V) publishes about backflow testing, from its own website.
- Who must test
- Homes and businesses with an irrigation system, a fire suppression service line, a compressor system or other added features on the water service line.
- New residential services get a 1 inch double check valve, commercial domestic services an RPZ device, and commercial fire service lines a double check valve.
- The Water and Sewer Division will inspect a water system at no charge to decide whether a device is needed.
- How often
- Every year, as the NYS and Nassau County health departments require and the Village code enforces.
- A new device is inspected by the Water and Sewer Division and tested before the water is turned on.
- If a device is not tested
Skipping the initial or annual test, or the DOH-1013, can lead to a summons and a fine.
- How reports are filed
- The tester sends the completed DOH-1013 to the Water and Sewer Division by fax or by email.
- The Village's RPZ typical plan says RPZ test reports go to both the Village and the Nassau County Department of Health.
- What each report must include
- The DOH-1013 completed, signed and dated by the tester.
- In the Remarks section, the material of the incoming water service where it enters the building, such as copper or lead.
- Who can test
A licensed, qualified backflow tester certified by the NYS Department of Health.
- New devices
- The Village installation application, the DOH-347 and the Nassau County Department of Health fee transmittal form.
- Homes may use the Village typical plan for a double check valve; an installation that cannot follow a typical plan needs plans sealed by a licensed engineer or architect.
- After approval, a Village plumbing permit from the Building Department, and all residential service materials, including the 1 inch double check valve, bought from the Water and Sewer Division.
- The county plan review fee runs from $140 for a residential double check valve to $485 for an RPZ larger than 2 inches.
- Questions
- Water and Sewer Division, (516) 746-0751, weekdays 8:30 AM to 4:30 PM, 155 Washington Avenue, Mineola.
- Building Department, (516) 746-0750, for plumbing permits.
Checked Nov 19, 2026 on the district's website: Water and Sewer, Backflow device and annual inspection notice (PDF), Water service and backflow device installation application (PDF). Rules can change, so confirm a date with the district before you rely on it.
About this district
System characteristics
- Population served
- 20,600
- Water source
- Groundwater
- PWSID
- NY2902839
- County
- Nassau County, NY
A note from the district
Submissions are processed within 3-5 business days.
Nearby
Other districts in Nassau County
- Albertson WDNassauRoslyn Heights13,500 servedTMB
- Submit DOH-1013 via Potaflow StartBayville (V)NassauBayville6,700 servedEmail
- Submit DOH-1013 via Potaflow StartBethpage WDNassauBethpage33,000 servedEmail
- Submit DOH-1013 via Potaflow StartCarle Place WDNassauCarle Place9,005 servedEmail
District details sourced from NYS DEC Public Water Supply Service Areas and NYS DOH Public Water System Contact Reports. If you represent Mineola (V) and notice an error, please let us know.